ccf-core/ccf-agent v1.0.1: hard min-gate coupling, QAC trust updates, and runtime certificates. Gate C exercised the computed runtime on Seed-class ARM hardware with driver-fed input. Unless a post cites a specific run, do not read it as proof of live sensors, mBot2 behaviour, Cognitum store validation, or production deployment.A robot that cannot hear you cannot know your call is over
A real moment
This household is invented for illustration. Nuala lives in a terraced house in Tuam with a small robot on the kitchen counter. At ten past ten the bank rings about her late husband's account. She says "privacy, please". The robot's microphone goes dead at the hardware, a shutter drops over its camera, and it turns to face the kettle.
The call takes eleven minutes. She puts the phone down and stays at the table with her tea.
At two her sister Carmel calls in to talk about their mother going into care. Nuala asks for privacy again. They talk for forty minutes, then Carmel goes and the front door closes behind her.
Two private moments in one day. The question this post is about is simple. How does the robot know when each one is over?
Why this matters
A privacy mode that only promises not to listen is easy to build and hard to believe. The CCF design does the harder thing. It switches the microphone off at the hardware and covers the camera, so the person can see that the robot is not watching.
That creates a new problem at the other end. The robot cannot hear "you can look now". It cannot see the phone go down. Whatever ends privacy has to work without the senses privacy switched off. Get it wrong one way and the camera comes back on in the middle of a hard conversation. Get it wrong the other way and the robot sits facing the wall long after you wanted it back.
What CCF does about it
The filing that covers this (US provisional 63/994,113, extension 4) lists the ways privacy mode can end, including a timeout and contextual sensing. It gives no settings. So we built both in Rust and ran them against the same 113,757 private moments in 2,000 simulated kitchens over 60 days.
The clock is the simple one: privacy ends a fixed time after it was asked for. The sensing we used is the only kind that needs no microphone or camera, a small presence sensor that counts people in the room. Privacy ends when the count drops below what it was when privacy started and stays down for five minutes. A visitor walking out drops it from two to one.
The trust the robot gives for being asked is worked out the same way whichever rule ends privacy. It does not depend on how long the private moment lasted. In the run, every household whose moments each produced one privacy record ended the 60 days with exactly the same trust value, to the last bit, whatever ended it.
The numbers
With a 30-minute clock alone, the robot turns back at half two in the middle of Nuala and Carmel's conversation. In the run that happened to 48.70% of visits. After the bank call, the same clock keeps the robot facing the kettle for nineteen more minutes. Stretch the clock to an hour and the robot faced the wall 43.58 minutes on average after a moment was over.
The people counter is good at visits. The better of the two we tested ended none of them early and turned the robot back about four minutes after the visitor left. It is no use for the bank call. Nuala never left her chair, so the count never changed. Without a clock, 70.20% of calls never ended at all, and a sensor that never misses did no better.
So you need both. With the counter and a 60-minute clock, visits end soon after the visitor goes, and 12.04% of them, the ones over an hour, still get cut once. Calls are left to the clock and wait 35.78 minutes on average. Checking the sensor once a minute costs about 6 nanoseconds.
What this doesn't solve
Nothing here lets the robot know a call is over when you stay put. The clock decides those, and every setting is wrong for some calls. A jumpy motion sensor also ends privacy early on someone sitting very still unless it waits several minutes. This is a simulation: the kitchens, moment lengths and sensor miss rates are invented, so trust the order of the results more than the exact percentages. This run also found limits in some filed settings. The fixes are in the filing queue (#691, #692) and will be written up once they are filed.
For the curious
The trust credit is the filed rule (Claim I(d)-(e)), passed through the hard min-gate from US 63/988,438 using hard_min_gate_step from the published ccf-core crate. It never reads duration, which is why the trust values matched to the bit. The full tables, including two sensor types and five clock settings, are in the gist below.
Where this fits
The research note with every table: https://gist.github.com/Hulupeep/27a8d03f1a8b749783e776a45996fb91 Earlier posts covered how the robot earns trust from privacy requests and how it comes back afterwards. Code and research crates: https://github.com/Hulupeep/ccf. Spec tooling: https://github.com/Hulupeep/Specflow.
License & contact
Research code under BSL 1.1, converting to Apache 2.0 in 2032. Licensing and contact: https://floutlabs.com.